UK homes · for people starting out in construction
Basics for England. Scotland, Wales and Northern Ireland have their own rules. The design, the manufacturer and building control always come first.
Required = the regulations ask for it · Recommended = official or industry guidance · Typical = normal site practice
See also: Parts of a house




| Kitchen: Worktop: ~900 mm high, 600 mm deep | Manufacturers |
| Kitchen: Wall units: 450–500 mm above the worktop | Manufacturers |
| Kitchen: Cooker hood: as the manufacturer says; if not stated, 650–750 mm above the hob | Approved Document F, UK |
| Kitchen: Sockets ≥300 mm from the sink bowl edge (BS 7671 sets no distance) | IET / Electrical Safety First |
| Kitchen: Sockets ≥100 mm from the hob and never above it | Electrical Safety First |
| Kitchen: Under-worktop appliances: reachable isolator switch above the worktop | Electrical Safety First |
| Kitchen: Sink, hob and fridge close together, nothing in the way (work triangle) | Design practice |
| Kitchen: Extract: 30 l/s with a hood to outside; 60 l/s without one | Approved Document F, UK |
| Kitchen: Heat alarm in the kitchen, not a smoke alarm | BS 5839-6, UK |
| Bathroom: Zone 0 (inside the bath): IPX7 and safety extra-low voltage (SELV) only | BS 7671 (701), UK |
| Bathroom: Zone 1 (above the bath up to 2.25 m): IPX4, fixed equipment only | BS 7671 (701), UK |
| Bathroom: Zone 2 (0.6 m around zone 1): IPX4 | BS 7671 (701), UK |
| Bathroom: 230 V sockets ≥2.5 m from the edge of zone 1 (shaver unit excepted) | BS 7671 (701.512.3), UK |
| Bathroom: All bathroom circuits protected by a 30 mA RCD (residual current device) | BS 7671 (701), UK |
| Bathroom: Light on a pull-cord switch or a switch outside: never touched with wet hands | Common practice |
| Bathroom: Extract fan: 15 l/s | Approved Document F, UK |
| Bedroom and living room: Sockets and switches: centre 450–1200 mm above the floor (new homes) | Approved Document M, UK |
| Bedroom and living room: Light switch ~1200 mm, on the handle side of the door | Common practice |
| Bedroom and living room: Consumer unit: switches at 1350–1450 mm | Approved Document M, UK |
| Bedroom and living room: Smoke alarms in hallways and landings on every floor, mains with battery back-up | Approved Document B, UK |
| Bedroom and living room: Upper-floor escape window: ≥0.33 m², ≥450 × 450 mm, bottom ≤1100 mm | Approved Document B, UK |
| Doors: Leaf sizes: 762 × 1981 mm and 838 × 1981 mm (also 686 and 610 mm) | Manufacturers |
| Doors: Entrance door: clear opening ≥775 mm | Approved Document M, UK |
| Doors: Entrance-floor doors: clear opening 750–800 mm depending on the hallway | Approved Document M, UK |
| Doors: Handle ~1000 mm (850–1000 mm required in wheelchair homes) | Approved Document M, UK |
| Doors: House–integral garage door: 30-min fire door with self-closer (FD30S / E 30 Sa) | Approved Document B, UK |
| Doors: Loft conversion or 3-storey house: fire doors onto the stair (min. FD20 / E 20) | Approved Document B, UK |
| Stairs: Rise 150–220 mm; going 220–300 mm; pitch ≤42° | Approved Document K, UK |
| Stairs: Headroom ≥2.0 m (less allowed in loft conversions) | Approved Document K, UK |
| Stairs: Handrail 900–1000 mm; both sides if the stair is ≥1000 mm wide | Approved Document K, UK |
| Safety glass: Doors and panels within 300 mm of a door: safety glass up to 1500 mm | Approved Document K, UK |
| Safety glass: Windows and walls: safety glass below 800 mm | Approved Document K, UK |
See also: Parts of a house